Skip to content

EMC measurements and consulting for reliable product development

We support your team with pre-compliance EMC measurements, root cause analysis and concrete optimisation recommendations – before EMC problems get expensive.

Device under test on the turntable of the fully anechoic chamber
Fully anechoic chamber Harbke
Frequency range up to 10 GHz, antenna distance up to 3 m, chamber dimensions 4 × 4 × 8 m (H × W × L)
Shielded chamber Meine
Complementary shielded test environment, AC single-phase, up to 16 A, DC up to 60 V, 10 A

Two test environments.One shared EMC capability portfolio.

Our fully anechoic chamber in Harbke and shielded chamber in Meine together form our EMC capability portfolio. We choose the right environment and test setup based on your device under test and your question.

Emissions

  • radiated emissions
  • conducted emissions

Immunity

  • radiated immunity
  • conducted immunity
  • ESD
  • surge and burst

Diagnostics and optimisation

  • near-field investigations
  • root cause analysis
  • verification of optimisation measures
Fully anechoic chamber operated by SAMD Solutions in Harbke, with antenna mast and turntable

Fully anechoic chamber, Harbke

Test environment up to 10 GHz

Frequency range
up to 10 GHz
Antenna distance
up to 3 m
Chamber dimensions
4 × 4 × 8 m (H × W × L)
AC supply
three-phase, up to 32 A
DC supply:
0–60 V, up to 10 A
Apparent power:
approximately 22 kVA

Showing: 01 / 02 – Fully anechoic chamber, Harbke

Not just measuring. Understanding and improving.

A measurement report on its own does not move your development forward. We work in four steps, repeated as often as development requires.

  1. 01

    Measure

    Record the device under test and its operating states in a traceable way.

  2. 02

    Analyse the cause

    Narrow down the interference source in the setup, on a cable, the board or the enclosure.

  3. 03

    Develop a measure

    Derive concrete changes for layout, cabling, filtering or shielding.

  4. 04

    Re-measure

    Verify and document the effect under identical conditions.

See the full process

What we do

Detect EMC problems early, understand their causes and verify solutions during development. Our measurements are pre-compliance measurements and do not replace testing by an accredited body.

Pre-compliance EMC measurements

Measurements on prototypes or pre-series units. You receive measurement data, a technical assessment against the relevant limits and traceable documentation of the setup.

  • Radiated and conducted emissions
  • Immunity testing, ESD, surge, burst and near-field investigations
  • Measurements across several operating states
See details

Root cause analysis and optimisation

When measured values stand out, we look for the cause in the setup and derive concrete measures from it. We verify the effect in a re-measurement under identical conditions.

  • Near-field investigation to locate the source
  • Measures for layout, cabling, shielding and enclosure
  • Re-measurement for verification
See details

EMC consulting

Technical support around the measurement: clarifying requirements, defining the measurement strategy, reviewing setup and layout together, and putting the results into context.

  • Clarifying requirements and standards
  • Measurement strategy and test plan
  • Layout and setup review
See details

Measurement options in detail

All EMC services at a glance

Orientation

Which kind of support fits your situation?

Find the line that comes closest to your situation. If none of them fits, we will work out the question together.

Would you like to read up on the terminology before commissioning a measurement? EMC knowledge, checklists and technical orientation collects the fundamentals, standards and preparation guides - sorted by topic.

Working together

Who we work with – and in what situation

On the left, the people we deal with. On the right, the situations in which they come to us.

Who we work with

  • Development

    Hardware and electronics teams that want to know where their setup stands in EMC terms.

  • Engineering and project management

    People who have to reconcile EMC risks with the dates in the project plan.

  • Quality management

    Roles that need traceable measurement data and clean documentation.

  • Purchasing and management

    Decision-makers for whom effort, deadlines and the risk of a change matter.

When we help

  • A prototype or pre-series unit needs a first EMC assessment.
  • A measurement shows anomalies and the cause is still unclear.
  • Before an external test, it needs to be clear which limits are critical.
  • A change to layout, cabling, filtering or enclosure needs to be verified.
  • The design freeze is approaching and there is no measured evidence yet.

Development teams that measure with us

VolkswagenIAVNovusForschnergood projects
“I will not forget working with SAMD Solutions any time soon. Quite apart from the fact that Stefan and Helge are technically beyond any doubt, every meeting and every phone call was a genuine pleasure. Thoroughly likeable people who can lift an entire project team with humour and composure, even in situations that look hopeless.”
Sebastian Bednarek
CEO, good projects GmbH
Translated from the original German
“For us at Novus, working with SAMD Solutions was a real game changer. As a young company in the early stages of product development, it mattered to us to find a partner who understands our agility and responds flexibly to our needs. SAMD Solutions delivered exactly that.”
René Renger
Managing Director, Novus GmbH
Translated from the original German

About EMC Labs by SAMD Solutions

You talk directly to the people who do the measuring and the evaluation – no order desk in between. You will receive a prompt response on the most suitable measurement option.

2
test centres
Fully anechoic chamber in Harbke, shielded chamber in Meine
since 2018
in business
Founded as an engineering services provider
More about us

Request a measurement slot

Briefly describe your device under test, its development stage and your timeframe. You will receive a prompt response on the most suitable measurement option.

How we can help

If you are not sure which measurement fits, please select “Not yet clear – please advise me”.

Fields marked * are required. Information on how we process your data is available in our privacy policy. Measurements and consulting are subject to our terms and conditions.

Direct contact

Test centres

  • Harbke – Fully anechoic chamber
    Test environment up to 10 GHz
  • Meine – Shielded chamber
    Complementary shielded test environment