Skip to content

Our two test environments

The fully anechoic chamber in Harbke and the shielded chamber in Meine together make up our measurement and investigation portfolio. The test types are not tied to one of the two environments – the choice follows from the test method, the device under test and the engineering question. We clarify this before scheduling.

Fully anechoic chamber in Harbke with antenna mast and turntable
Service
Development-stage EMC measurements and investigations
Location
Harbke and Meine
Frequency range Harbke
up to 10 GHz

Two test environments. One shared EMC capability portfolio.

Our two test environments together form the EMC capability portfolio of EMC Labs. The appropriate environment and test setup depend on the test method, device under test, supply requirements, setup and engineering question.

Emissions

  • radiated emissions
  • conducted emissions

Immunity

  • radiated immunity
  • conducted immunity
  • ESD
  • surge and burst

Diagnostics and optimisation

  • near-field investigations
  • root cause analysis
  • verification of optimisation measures

These capabilities are provided across our two test facilities. The appropriate facility and test setup are selected for each project.

Request the right test environment
Fully anechoic chamber operated by SAMD Solutions in Harbke, with antenna mast and turntable
Am Glüsig 1C, 39365 Harbke (Saxony-Anhalt)

Fully anechoic chamber, Harbke

The fully anechoic chamber in Harbke provides a spacious measurement environment for development-stage EMC investigations. The frequency range extends up to 10 GHz and the maximum antenna distance is 3 m.

Frequency range
up to 10 GHz
Antenna distance
up to 3 m
Chamber dimensions
4 × 4 × 8 m (H × W × L)
DC supply
0–60 V, up to 10 A
AC supply
three-phase, up to 32 A
Apparent power
approximately 22 kVA

The figure of 4 × 4 × 8 m describes the internal dimensions of the chamber, not the maximum size of the device under test. The size that can actually be accommodated depends on the setup, the cabling, the peripherals and the measurement distances required, and is agreed on a project-by-project basis.

Test setup in the shielded chamber operated by SAMD Solutions in Meine, with measurement equipment
Peiner Straße 16, 38527 Meine (Lower Saxony)

Shielded chamber, Meine

The shielded chamber in Meine complements the fully anechoic chamber with a separate test environment for development-stage investigations, diagnostics and the verification of optimisation measures.

AC supply
single-phase, up to 16 A
DC supply
up to 60 V, 10 A

Equipment

What we work with at both sites. What is used in a specific case follows from the measurement plan.

  • Spectrum analysers and measurement antennas
  • Near-field probes for locating interference sources
  • ESD, surge and burst generators
  • Line impedance stabilisation networks for conducted tests
  • Adjustable DC and AC supply for the test setup
  • In-house workshop for adjustments to the test setup

Are you looking for measurement time in one of the two chambers rather than a full measurement assignment? Chamber rental with engineering support explains how measurement time with our engineers works.

Arrange a visit or a measurement slot